Single Point Cycles
The Single Point X, Y and Z cycles are defined with the following parameters:
Approach/Retract
- The Distance value defines the Probe tool position before or after performing the measurement cycle.
- The direction button enables you to define the direction of the tool path relative to the plane.
Levels
- The Z Level value defines the Z-coordinate of the contact point. The selection button enables you to select the point directly on the model by using the Pick on plane dialog box.
Modify geometry
- The Offset value defines an additional distance from the contact points in the same direction as the approach/retract distance.
Rotation angle (available for X and Y only)
- This field enables you to set the angle the tool approaches the plane with.
- The arrow button enables you to select the plane the angle relates to.
Repetitive touches
- This field enables you to define the number of touches in each contact point.