Turret Stations


Stations enable you to define the tool mounting positions relative to the Turret CoordSys.

Any number of stations can be defined, each by the following parameters:

Name

Enter the name of the station

Station Number

Station number in the Tool Table (magazine or on rotary/linear turret)

Default Tool Direction

The Tool direction (vector) when you start running the machine

CoordSys

The station coordinate system relative to the Turret Coordsys

Drive Type

Choose the station relation to the Drive Unit.(See types below)

Adaptor Type

Enter the type of the Adaptor compatible with the turret

Maximum Position Letter

Enter maximum positions of the station.

Each station may have a different Drive Type. The following types are available for selection:

NOT DRIVEN

Station cannot have live tool. Definition of Spin is not possible. Only Turning Tools are permitted.

SELF DRIVE

Station itself is a separate Drive Unit (independent of Turret Drive Unit).

GEAR

Change Spin received from Turret Drive Unit using defined ratio.

DIRECT FROM DRIVE UNIT

All Spin data are taken from Turret Drive Unit.

Managing Stations

To manage stations, right-click the Stations header and choose an option from the menu:

To create a set of stations on a turret, choose Create Stations. The Stations Creator dialog box is displayed.