MCO Misc. Options
This subheader enables you to define and manage MCO options that provide miscellaneous control of the machine devices.
The defined options will later be available for use in Machine Control Operations when using the General technology.
MCO option Main Parameters
The MCO Option definition requires the following general information:
GUI Name | The option name, which can be written in any language, displayed in the Process pane of the operation after dragging and dropping the Misc device icon from the Devices Library (Action on...) pane. |
GPP Name | The parameter name written with Latin characters set only (supported by the post-processor and used in the *.gpp file). |
Parameters with an option
Each MCO Option can also include any number of optional parameters, enabling you to control its functionality.
Each parameter is defined as follows:
GUI Name | The parameter name, which can be written in any language, displayed in the Properties pane of the operation. |
GPP Name | The parameter name written with Latin characters set only (supported by the post-processor and used in the *.gpp file). |
Type | Choose the parameter type from the list: NUMERIC, LOGICAL, INTEGER or STRING). |
Default Value | Defines the default value of the parameter, which can be later modified in the Properties pane. |
Description | Enter a short description of the parameter. |