Turning Misc. Parameters
This subheader enables you to define and manage any number of miscellaneous parameters that can be used in Turning operations.
This option enables you to define all Misc. Parameters for Turning operations.
In earlier versions of SolidCAM, the Misc. Parameters were defined in the *.prp (*.mac) file.
Each parameter is defined as follows:
GUI Name | The parameter name, which can be written in any language, displayed in the Extra parameters section on the Misc. parameters page of Turning operations. The availablility of parameters is determined by the Used In selection. |
GPP Name | The parameter name written with Latin characters set only (supported by the post-processor and used in the *.gpp file). |
Type | Choose the parameter type from the list: NUMERIC, LOGICAL, INTEGER or STRING). |
Default Value | Defines the default value of the parameter, which can be later modified in the operation. |
Used in | Choose what operations can use the parameter. |
Description | Enter a short description of the parameter. |